6 - 12
Category
Controller errors
ERROR nn
Error Remedy
LCD status message Trouble or status Remedy
Replace the Main Control PCB.0n A fault occurred in the
controller.
n = Exception Code
Replace the Main Control PCB.10 An error was detected by
program ROM check.
Replace the Main Control PCB.20 An error was detected by
font ROM check.
Replace the Main Control PCB.30 An error was detected by
resident RAM check.
Replace the EEPROM or Main
Control PCB.
EEPROM
40 An error was detected by
EEPROM check.
Check the optional software ROM
board for proper connection or
replace it.
50 An error was detected by
optional software ROM
check.
Code
(nn)
Table 6-2 (Cont'd)